Table 1 Device attributes | ||||
Product Type |
Description |
BOM |
Model |
Earliest Software Version |
NE40E-X3A DC |
NE40E-X3A Integrated DC Chassis Components (Including Dual DC Power) |
02350FMK |
CR5B0BKP0373 |
V800R007C00 |
NE40E-X3A AC |
NE40E-X3A Integrated AC Chassis Components (Including Dual AC Power) |
02350FML |
CR5B0BKP0374 |
V800R007C00 |
Appearance of Huawei NE40E-X3A
Figure 1 Appearance
Components |
Figure 2 Components (front view)
1. Handle |
2. Air intake vent |
3. Cabling rack |
4. Rack-mounting ear MPU |
5. Fan |
6. Fan module cage cover |
7. LPU |
8. ESD jack |
9. MPU |
Figure 3 Components (rear view)
10. Ground terminal |
11. Air exhaust vent |
12. Air filter |
13. Power module |
Slot Layout |
Figure 4 Slot layout
Table 2 Description of slot layout | |||
Slot Name |
Slot Quantity |
Slot ID |
Remarks |
LPU |
3 |
1 to 3 |
These slots hold LPUs. |
MPU |
2 |
4 to 5 |
These slots hold MPUs. |
Technical Specifications of Huawei NE40E-X3A
Item |
Specification |
Dimensions (H x W x D) |
●(6 U) 264 mm x 442 mm x 710 mm (10.39 in. x 17.40 in. x 27.95 in.) (Chassis main body) ●DC: (6 U) 264 mm x 442 mm x 758 mm (10.39 in. x 17.40 in. x 29.84 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) ●AC: (6 U) 264 mm x 442 mm x 770 mm (10.39 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Weight (empty) |
26 kg (57.33 lb) |
Weight (full configuration) |
●DC: 72.1 kg (158.98 lb) ●AC: 74.7 kg (164.71 lb) |
Cabinet installation standard |
Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Typical power consumption |
1120 W (fully configured with LPUF-200s) |
Typical heat dissipation |
3633.8 BTU/hour (fully configured with LPUF-200s) |
DC input voltage |
●input voltage range: –40 V to –72 V ●input rated voltage: –48 V/ –60 V |
AC input voltage |
●input voltage range: 180 V to 264 V ●input rated voltage: 200 V to 240 V |
MTBF |
22.85 years |
MTTR |
0.5 hours |
Availability |
0.999997502 |
Slot quantity |
5 |
Redundant MPUs |
1:1 |
Redundant Switch fabrics |
N/A |
Redundant fans |
Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Redundant power supply |
1+1 |
Forwarding performance |
900 Mpps (LPUF-200) |
Switching capacity |
2.79 Tbps |
Operating temperature |
●Long-term: 0°C to 45°C (32°F to 113°F) ●Short-term: –5°C to +55°C (23°F to131°F) ●Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Relative operating humidity |
●Long term: 5% to 85% RH, non-condensing ●Short term: 5% to 95% RH, non-condensing |
Relative storage humidity |
5% to 95% RH, non-condensing |
Long-term operating altitude |
= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].) |
Storage altitude |
Less than 5000 m (16404 ft.) |