Product details
Product Description:
Outdoor drop fuse is suitable for up to and including 35 kv voltage frequency 50 hz in the power system, transmission lines, power transformer overload and short circuit protection, only device.the rated load current, a mechanical life 2000 times or more
Drop type fuse and tensile load falling type fuse is outdoor high voltage protection appliances, it assembled in distribution transformer high voltage side or distribution lines trunk road, transmission lines, power transformer overload and short circuit protection and device.the rated load current. According to fuse protection, the large amount of open circuit current should be no less than the maximum short-circuit current of protected electrical circuit;Minimum melting current should be no greater than was the minimum short circuit current protection circuit.
When installing fuse, should tighten all of the parts, to prevent contact part overheating during normal operation.
For three-phase install fuse piece, even if an action, the other two shall be replaced, because the other two, though not damaged, but is close to a point, to the extent of the damage.Vacuum fuse
Fuse cannot be installed on the severe vibration, dust, pollution, moist places.
The fuse save and check the fuse installation and replacement
To fall or the vibration of the fuse should be tested before use (dc resistance, the parts are in good condition)
Place a long time of fuse factory/outbound should be check again when the resistance value.
Fuse should be stored in dry places.
In replacement of fuse piece, should be replaced in the action after 10 minutes. If after fusing a movement found smoke emission tube or noisy phenomenon, should not replace the fuse, need, fusing and isolation are allowed to change after a power source.
For in near the power supply device or a charged conductor, should meet the safety regulations
1.ISO9001,C
2.90%exportation
3.good quality and reasonable price

Product Description
Outdoor Fuse Cutout 10KV-36KV
Application: Protection device for protecting power system from over-load and short-circuit failure. 
Ratings: 10kV-36kV. 
Standards: IEC 600282-2

Features: 
1, High over-current protection capability, high breaking current. 
2, High industrial frequency withstands voltage, and mechanical strength, etc. 
3, High quality on strict testing. 

Technical Data: 
Rated voltage: 11kV to 66kV. 
Rated current: Up to 200A. 

main technical parameters
 
 
 
TYPE
 
Rated
Voltage
(KV)
 
Rated
Current
(A)
 
Breaking
Current
(A)
 
Impulse
Voltage
(BIL)
(KV)
 
Power-frequency wishtand voltage
(KV)
 
Leakage
Distance
(MM)
Voltage
 
Weight
(KG)
 
Dimensions
(CM)
RW3 10 100 6300 100 42 230 6.2 48X27X12
RW3 10 200 8000 100 42 230 6.5 48X27X12
HRW3 10 100 6300 100 42 230 6.2  
HRW3 10 200 8000 110 42 230 6.2  
RW7 10 100 6300 110 42 230 6.2 48X27X12
RW7 10 200 8000 110 42 230 6.5 48X27X12
HRW7 12 100 6300 110 42 230 6.2  
HRW7 12 200 8000 110 42 230 6.2  
RW10-10F 12 100 6300 110 42 260 7.5 53X32X12
RW10-10F 12 200 8000 110 42 260 7.5 43X32X12
HRW10 12 100 6300 110 42 260 7.5  
HRW10 12 200 8000 110 42 260 7.5  
RW12 15 100 10000 110 40 250 7.5 40X34.5X11
RW12 15 200 12000 110 40 250 7.5 40X34.5X11
RW12 24 100 8000 150 65 540 12 49X35X14
RW12 24 200 12000 150 65 540 12 49X35X14
RW12 30 100 6000 170 70 700 15 56X38X14.5
RW12 30 200 8000 170 70 700 15 56X38X14.5
RW12 33 100 10000 170 70 720 15.5 57X38X14.5
RW12 33 200 12000 170 70 720 15.5 57X37X14.5
RW12 11 100 6000 110 42 340 7.5 49X27X11.5
RW12 11 200 8000 110 42 340 7.5 49X27X11.5
RW11 36 100 6000 110 42 340 16 90X40X13
RW11 36 200 8000 170 70 870 16 90X40X13
RW5 33 100 8000 170 70 820 27.5 67X17X15
RW5 33 200 10000 170 70 820 27.5 68X17X15
HRW9 10 100 6300 110 42      
HRW9 10 300 8000 110 42      
HRW11 12 100 6300 100 42      
HRW11 12 200 8000 110 42      
HPRW11 12 100 6300 100 42      
HPRW11 12 200 8000 110 42      
HRW12 12 100 6300 100 42      
HRW12 12 200 8000 110 42